We are the Manufacturer of Tata Power Generators. Tata Power Generators have the least Fuel Consumption.
DG SETS | DG Set Model | RT-20^ | RT-25 | RT-30RT-35 |
RT-40 |
RT-45 |
RT-50 |
RT-62.5 |
RT-75 |
RT-82.5* |
RT-83 |
RT-100 |
RTS-125 |
RT-125 |
|
Rating (kVA) | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 62.5 | 75 | 82.5* | 82.5 | 100 | 125 | 125 | |
Rating (kW) | 16 | 20 | 24 | 28 | 32 | 36 | 40 | 50 | 60 | 66 | 66 | 80 | 100 | 100 | |
ACOUSTIC ENCLOSURE | Starting System | 12V DC | |||||||||||||
Battery (Ah) | 90 | 100 | |||||||||||||
Canopy Size : LxBxH (mm) | 2350 x 1030 x 1425 | 2850 x 1100x 1550 | 3200 x 1200 x 1800 | ||||||||||||
Weight (Kg) | 950 | 1000 | 1020 | 1030 | 1040 | 1450 | 1500 | 1520 | 1580 | 1610 | 1750 | 1800 | 1850 | 2050 | |
Fuel Tank Capacity (Ltrs) | 130 | 180 | 250 | ||||||||||||
Thickness of Foam In doors | 40 | 50 | 75 | ||||||||||||
Density of Foam for Sound Insulation | 32 | 38 | 50 | ||||||||||||
Steel Make & Thikness in Acoustic | TATA Steel |Base 3 mm | Rest of Canopy 1.6 mm | ||||||||||||||
Engine | Engine Model Family | 497SP | 497SPTC | 497TC | 697TC | ||||||||||
Engine Make | TATA | ||||||||||||||
Engine Power (Bhp) | 32.5 | 40.2 | 48.2 | 56.3 | 56.3 | 56.3 | 75.7 | 90 | 99.8 | 99.8 | 120 | 125.3 | 156 | 156 | |
Rated Speed (RPM) | 1500 | ||||||||||||||
No. of Cylinders | 4 | 6 | |||||||||||||
Bore (mm) | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | 97 | |
Stroke (mm) | 100 | 100 | 100 | 100 | 100 | 100 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | 128 | |
Total Displacement (CC) | 2960 | 3800 | 5700 | ||||||||||||
Lube oil Sump Capacity (Ltrs) | 7 | 10 | 15 | ||||||||||||
Total Coolant Capacity (Ltrs) | 13 | 14 | 18 | ||||||||||||
Oil Changed Period | 500 Hrs Or 6 Months Which Ever Is Earlier | ||||||||||||||
Compression Ratio | 17.5 : 01 | ||||||||||||||
Aspiration | Natural | Turbo Charged | |||||||||||||
Cooling System | Water/Coolant | ||||||||||||||
FIP | MICO Bosch - Inline Pump | Rotary/Inline Pump | Rotary Pump | MICO Bosch - Inline Pump | |||||||||||
Governing Type | Mech-A1 Governing | Electronic/ Mech-A1 Governing | Electronic-A0 Governing | Mech-A1 Governing | |||||||||||
Emission Norms | CPCB-II Compliant | ||||||||||||||
ALTERNATOR | Alternator Make | Stamford | |||||||||||||
Type (PF) | Brushless, H Class Insulation | (0.8) | ||||||||||||||
Frequency (Hz) | 50 / 60 | ||||||||||||||
Voltage (V) | 230/415 | 110/230 | ||||||||||||||
Amperes (A) @ 415 V | 27 | 34 | 41 | 48 | 55 | 62 | 69 | 86 | 104 | 114 | 114 | 139 | 173 | 173 | |
CONTROLLER | Controller Make | WoodWard 1400 | WoodWard 1400 / 600 | ||||||||||||
Type | Microprocesser Based, LCD fault display screen, Auto start / Stop Features | ||||||||||||||
Display Parameters | Run Time Hours, Current, Voltage, Engine RPM, Frequency, Engine Temperature & Oil Pressure, Battery V, Service Due Hours, kVA, PF, KW, KWH | ||||||||||||||
Modes Available | Automatic/ Manual | ||||||||||||||
DG Protections | Under/Over Frequency ,Current Unbalance, Over Speed, Overload, RWL, LLOP, HWT, LFL, Charging Alternator/V-belt, Emergency-Off, Service Due Fail To Start Fail To Stop | ||||||||||||||
MCB/MCCB | SCHNEIDER / ABB | ||||||||||||||